1. Overview
The cellulosic welding electrode has a high-cellulose coating and is designed for DCEP welding. It is intended for vertical-down welding of pipeline girth seams in all positions and is also suitable for general carbon steel structures. It produces a forceful, deep-digging arc and is suitable for single-sided welding with a clean root bead on the back side.
1.1 Standards
| Standard |
Classification |
| AWS A5.1 |
E6010 |
| GB/T 5117 |
E4310 |
| ISO 2560-B |
E 43 10 A |
2. Coating and Operating Characteristics
- Coating: high-cellulose; designed for DCEP (direct current electrode positive) welding.
- Vertical-down welding of pipeline girth seams in all positions.
- Forceful arc with strong digging action.
- Single-sided welding with a clean root bead on the back side.
- Good resistance to porosity and hot cracking.
- Typical applications: girth butt welding of 430 MPa-grade carbon steel pipelines and general carbon steel structures.
| Element |
C |
Mn |
Si |
S |
P |
Ni |
Cr |
Mo |
V |
| Guaranteed |
≤ 0.20 |
≤ 1.20 |
≤ 1.00 |
≤ 0.035 |
≤ 0.040 |
≤ 0.30 |
≤ 0.20 |
≤ 0.30 |
≤ 0.08 |
| Typical |
0.09 |
0.42 |
0.15 |
0.020 |
0.025 |
0.030 |
0.035 |
0.005 |
0.004 |
| Property |
Tensile strength (Rm) |
Yield strength (ReL) |
Elongation (A) |
Impact energy (KV2) at -30 °C |
| Guaranteed |
≥ 430 MPa |
≥ 330 MPa |
≥ 20% |
≥ 27 J |
| Typical |
475 MPa |
400 MPa |
26% |
80 J |
X-ray inspection: Grade II (defect-free).
5. Recommended Welding Current
| Diameter (mm) |
2.5 |
3.2 |
4.0 |
| Length (mm) |
300 |
350 |
350 |
| Current (A), DCEP |
50–80 |
60–100 |
100–140 |
6. Welding Positions and Operating Notes
The electrode is designed for vertical-down welding of pipeline girth seams in all positions.
- Use DCEP for the root pass.
- Keep the arc short and avoid excessive weaving.
- Clean the joint area before welding.
- Clean slag between passes in multi-layer welding.